Welding operation
54 Operating Instructions Soyer Bolzenschweißtechnik
14.5 Malfunctions with an error message
When there is a stud welding device malfunction, an error message (code) ap-
pears on the display.
DANGER
!
Dangers during troubleshooting
During troubleshooting, various dangers may occur.
All devices of Soyer Bolzenschweißtechnik GmbH may only be opened by
personnel of Soyer or personnel authorised by Soyer.
For troubleshooting, the device must be disconnected from the main power
supply and secured against accidental switch-on.
Error
code
Description Possible cause
E01 Safety shutdown as a voltage of more
than 25 V was measured for more
than approx. 40 ms on the welding
power sockets.
Stud inserted too deep into the stud chuck
Mechanical problems with the gap welding gun
External voltage of other welding devices
Error in the device (thyristor short circuit)
E02 Error when charging the capacitors Welding capacitors faulty (leakage current)
Charging current source faulty