Parameter
Permitted values
Default
up.PersonalAlarm.running.sensitivity
0-7
0
0 disable, 1 least sensitive, 7 most sensitive
As the sensitivity increases the handset requires less movement to trigger a running alarm. The specific sensitivity
setting appropriate for a given application is site/user specific.
up.PersonalAlarm.running.timeout
5-60 (secs)
7
The running condition must persist for this amount of time before a warning occurs.
up.PersonalAlarm.suspendMonitoring
0- 300 (secs)
0
0, no suspension of monitoring is allowed, otherwise duration in seconds of the amount of time during which
motion event monitoring is disabled.
up.PersonalAlarm.warningTimeout
5-60 (secs)
10
This is the number of seconds a user has to disable the warning on the handset before the warning automatically
triggers an alarm.
up.PersonalAlarm.notificationEnable
0-1
1
Disable/enable local alarm notification (tone, vibrate, LED flash) on motion event detection in both warning and
alarm states.
up.PersonalAlarm.emergencyDialEnable
0-1
0
This parameter requires correct configuration of the Emergency Dial feature as detailed in the Spectralink
84-Series Administration Guide. This parameter is disabled by default.
If enabled, an emergency call is automatically placed when a running/tilt/still alarm occurs.
If disabled, and a running/tilt/still alarm occurs the emergency call will NOT be placed but the alarm state will be
activated.
Either way, the handset will transition into the alarm state and will generate an XML alarm notification if
apps.telNotification.alarmEvent is enabled.
up.PersonalAlarm.emerDialForceSpeakerPhone
0-1
1
This parameter requires correct configuration of the Emergency Dial feature as detailed in the Spectralink
84-Series Administration Guide. This parameter is enabled by default.
Allows you to force the speakerphone on an emergency call. If 1 force speakerphone on emergency call, if 0 use
normal audio termination routing rules (headset if connected, …).
ptt.emergencyDial.emergencyDialEnable
0-1
1
This parameter requires correct configuration of the Emergency Dial feature as detailed in Emergency . This
parameter is enabled by default.
If enabled, an emergency call will be placed if the duress button is pressed twice within two seconds.
If disabled, and the duress button is pressed twice within two seconds, the emergency call will NOT be placed but
the alarm state will be activated.
ptt.emergencyDial.longKeypressEnable
0-1
0
This parameter enables the long press method of activating the Emergency Dial function. It is disabled by default.
When set (1), it overrides the default double press method (0).
ptt.emergencyDial.longKeypressDuration
1,2,3,4
2
If the long press method of activating the Emergency Dial function is enabled, this parameter sets the length of
time in seconds that the key must be pressed in order for a call to be initiated.
ptt.emergencyDial.notificationEnable
0-1
0
This parameter requires correct configuration of the Emergency Dial feature as detailed in Emergency . This
parameter is disabled by default.
Disable/enable local alarm notification (tone,vibrate,LED flash) on manual button press (a duress or emergency
dial call). This parameter works in conjunction with Emergency Dial activation and applies to all handset models.