Spectralink 84-Series Series Wireless Telephones Administration Guide
1725-86984-000_P.docx
September 2016 152
The Alarm event notifies an application that a (personal security) alarm condition has been
detected or cleared on the handset.
Use the following format when viewing the alarm event:
<PolycomIPPhone>
<AlarmNotificationEvent>
<PhoneIP>172.29.71.157</PhoneIP>
<MACAddress>00907a0e4459</MACAddress>
<BSSID>0023ebe4ebaf</BSSID>
<StillAlarm>0</StillAlarm>
<TiltAlarm>1</TiltAlarm>
<RunningAlarm>0</RunningAlarm>
<DuressAlarm>0</DuressAlarm>
<TimeStamp>2012-12-10T08:11:25-07:00</TimeStamp>
</AlarmNotificationEvent>
</PolycomIPPhone>
Where
Phone IP is the IP address of the handset
MAC Address is the MAC address of the handset
BSSID is the MAC address of the AP the handset is currently using
StillAlarm is the current state of this alarm detector 0 = no alarm, 1 = alarm
TiltAlarm is the current state of this alarm detector 0 = no alarm, 1 = alarm
RunningAlarm is the current state of this alarm detector 0 = no alarm, 1 = alarm
DuressAlarm is the current state of this alarm detector 0 = no alarm, 1 = alarm
TimeStamp is the recorded time of the event
Configuration Template
The PersonalAlarm.cfg template is provided with the software download in the Config>Features
folder. Use it to as a starting point to customize your deployment of this feature.