EasyManua.ls Logo

SpectraLink 8440 - Page 68

SpectraLink 8440
335 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Spectralink 84-Series Series Wireless Telephones Administration Guide
1725-86984-000_P.docx
September 2016 68
This section shows you how to choose a default notification profile from four available types -
Normal, Silent, Meeting, Custom1 - and shows you the parameters you can set for each type.
Each profile is defined by an alert type and a ring type; there are 15 alert types and three ringing
types.
For each alert type:
You can select a tone pattern from the patterns defined in se.pat.misc. These patterns
include: custom1 to custom10, instantMessaging, localHoldNotification,
messageWaiting, misc1 to misc9, negativeConfirm, positiveConfirm,
remoteHoldNotification, silent, and welcome. For information on customizing these
parameters, refer to se.pat.misc.
You can determine if the handset should vibrate for the alert. Set the vibrate parameter
to 0 to disable vibration or 1 to enable vibration.
For each ringer type:
You can choose a tone pattern from the patterns defined in se.pat.ringer. These
patterns include: default, ringer1 to ringer 24, and 1 to 22.
You can also set the vibration type for the ringer. You can select off, continuous,
shortPulse, or longPulse.
Configure the default notification profile by setting the parameter shown in the following table:
Table 7-5: Notification Profile Selection Parameter
Parameter
Permitted Values
Default
np.selected
Normal, Silent, Meeting, Custom1
Normal
The initial profile that is selected when the handset powers on and active during operation. The user can override
this default profile to set a new default profile that will be selected when the handset powers on the next time.
Table 7-6: Normal Profile Alert Parameters
Parameter
Permitted Values
Default
np.normal.label
String
Normal
The name of the profile type.
np.normal.alert.barcodeBeep.tonePattern
np.normal.alert.barcodeBeep.vibration
Any tone (see se.pat.misc)
0 or 1
misc2
0
The tone pattern and vibration (1 to enable) for the alert played when a barcode is scanned.
np.normal.alert.docked.tonePattern
np.normal.alert.docked.vibration
Any tone (see se.pat.misc)
0 or 1
positiveConfirm
0
The tone pattern and vibration (1 to enable) for the alert played when the handset is docked.
np.normal.alert.undocked.tonePattern
np.normal.alert.undocked.vibration
Any tone (see se.pat.misc)
0 or 1
negativeConfirm
0
The tone pattern and vibration (1 to enable) for the alert played when the handset is undocked.

Table of Contents