Answer: (4 bytes)
INT32U CMD Command (answer)
Description:
Read all settings from controller's flash memory to controller's RAM, replacing previous data in controller's RAM.
Command SARS
result_t command_save_robust_settings (device_t id)
Command code (CMD): "sars" or 0x73726173.
Request: (4 bytes)
INT32U CMD Command
Answer: (4 bytes)
INT32U CMD Command (answer)
Description:
Save important settings (calibration coefficients and etc.) from controller's RAM to controller's flash memory, replacing previous data in
controller's flash memory.
Command RERS
result_t command_read_robust_settings (device_t id)
Command code (CMD): "rers" or 0x73726572.
Request: (4 bytes)
INT32U CMD Command
Answer: (4 bytes)
INT32U CMD Command (answer)
Description:
Read important settings (calibration coefficients and etc.) from controller's flash memory to controller's RAM, replacing previous data in
controller's RAM.
Command EESV
result_t command_eesave_settings (device_t id)
Command code (CMD): "eesv" or 0x76736565.
Request: (4 bytes)
INT32U CMD Command
Answer: (4 bytes)
INT32U CMD Command (answer)
Description:
Save settings from controller's RAM to stage's EEPROM memory, which spontaneity connected to stage and it isn`t change without it
mechanical reconstruction. Can be used by manufacturer only.
Command EERD
result_t command_eeread_settings (device_t id)
Command code (CMD): "eerd" or 0x64726565.
Request: (4 bytes)
INT32U CMD Command
Answer: (4 bytes)