EDIT PARAMETERS
Parameter
Name
Cold Units
(Stero Cold SU-L)
(Glass Washer:
Stero Cold SG)
Hot Units
(Stero Hot SU-H)
Description Possible Values Default Values
Booster
Temp Set
Pt.
N/A Stero Hot SU-H
Booster
temperature
set point.
FSP -12 to FSP +12 FSP 0
Sump
Temp Set
PT.
Stero Cold SU-L
Stero Cold SG
Stero Hot SU-H
Sump
temperature
set point.
120-170°F/49-77°C
130°F / 54°C
(Stero SU-L &
SG)
165°F / 77°C
(Stero SU-H units
only)
Detergent
Pump
Stero Cold SU-L
Stero Cold SG
Stero Hot SU-H
Detergent
pump option.
Disabled / Enabled Enabled
Detergent
Flow Rate
Stero Cold SU-L
Stero Cold SG
Stero Hot SU-H
Detergent flow
rate measured
in mL per cycle.
OFF through 20.0 mL 7.9 mL
Rinse Aid
Pump
Stero Cold SU-L
Stero Cold SG
Stero Hot SU-H
Rinse Aid
pump
operation.
Disabled / Enabled Enabled
Rinse Aid
Flow Rate
Stero Cold SU-L
Stero Cold SG
Stero Hot SU-H
Rinse aid flow
rate measured
in mL per cycle.
OFF through 8.8 mL 1.8 mL
Sanitizer
Flow Rate
Stero Cold SU-L
Stero Cold SG
N/A
Sanitizer flow
rate measured
in mL per cycle.
Off to 100 mL 60 mL
Detergent
PWM Freq
Stero Cold SU-L
Stero Cold SG
Stero Hot SU-H
DO NOT
ADJUST.
Contact Stero
technical
support.
5000-50,000 (by
1000's)
10,000
Rinse Aid
PWM Freq
Stero Cold SU-L
Stero Cold SG
Stero Hot SU-H
DO NOT
ADJUST.
Contact Stero
technical
support.
5000-50,000 (by
1000's)
10,000
Sanitizer
PWM Freq
Stero Cold SU-L
Stero Cold SG
N/A
DO NOT
ADJUST.
Contact Stero
technical
support.
5000-50,000 (by
1000's)
10,000
Detergent
Threshold
Stero Cold SU-L
Stero Cold SG
Stero Hot SU-H
Sets maximum
allowable
chemical
sense reading
(mV) for
detergent.
0-4000 (by 100's) 1100
SG, SU-L, SU-H DISHWASHERS - SERVICE PROCEDURES AND ADJUSTMENTS
Page 19 of 59 F45577 (1215)