EDIT PARAMETERS
Parameter
Name
Cold Units
(Stero Cold SU-L)
(Glass Washer:
Stero Cold SG)
Hot Units
(Stero Hot SU-H)
Description Possible Values Default Values
Rinse Aid
Threshold
Stero Cold SU-L
Stero Cold SG
Stero Hot SU-H
Sets maximum
allowable
chemical
sense reading
(mV) for rinse
aid.
0-4000 (by 100's) 2500
Sanitizer
Threshold
Stero Cold SU-L
Stero Cold SG
N/A
Sets maximum
allowable
chemical
sense reading
(mV) for
sanitizer.
500-4000 (by 100's) 1100
Rinse
Assurance
N/A Stero Hot SU-H
Lengthens
wash time, if
necessary, to
allow booster
to heat
incoming
110°F water to
180°F. Time
may vary.
Disabled / Enabled Enabled
Soft Start
Period
Stero Cold SU-L
Stero Cold SG
Stero Hot SU-H
Reduces
voltage and
current to wash
pump at
beginning of
wash cycle for
5-6 seconds.
Lower is not
softer and
higher is not
harder. If
unsure how to
adjust, call
Stero technical
support.
1.67 ms
2.09 ms
2.50 ms
2.92 ms
3.34 ms
3.75 ms
4.17 ms
4.59 ms
5.00 ms
5.42 ms
5.84 ms
6.26 ms
6.67 ms
4.17 ms
Exit Menu
Stero Cold SU-L
Stero Cold SG
Stero Hot SU-H
Exits
Parameter
Menu.
SG, SU-L, SU-H DISHWASHERS - SERVICE PROCEDURES AND ADJUSTMENTS