Messages about parked regeneration
The driver is informed of the need for a parked
regeneration by means of corresponding mes-
sages on the display-operating unit before
parked regeneration is due.
Shown on display Cause/action
Standstill regeneration not re-
quired
The particle filter is not saturated with soot. The
last parked regeneration was less than 1000
operating hours ago. Parked regeneration is
not necessary.
Standstill regeneration required
The particle filter is over-saturated with soot
or 1000operating hours have elapsed since
the last regeneration. Parked regeneration is
required.
-If possible, park the truck and perform the
particle filter regeneration.
Urgent standstill regeneration
required
Parked regeneration was not performed after
the first message appeared on the display-op-
erating unit, but is urgently required.
The maximum speed of the truck is reduced to
2km/h. The lifting speed is restricted.
-Park the truck and perform the particle filter
regeneration.
Start standstill regeneration?
Prompt asking whether parked regeneration of
the particle filter should be performed.
-Confirm or reject with Softkey.
Apply parking brake
The parking brake is released.
-Apply the parking brake.
Start internal combustion engine
The engine is not running.
-Start the engine.
Exhaust gas regeneration active
Do not switch off the engine
High exhaust gas temperatures
can occur
The particle filter is being regenerated.
A status bar shows the regeneration progress.
Standstill regeneration comple-
ted
The parked regeneration process is complete.
The truck is ready for operation again.
Operation
4
Particle filter system
296 57378011527EN-12/2023 - 07

Table of Contents