7 Teleservice Application Framework
User Manual 242/374
Output:
Variable
Variable Type
Description
error_code
uint16
0: no error occurred, else command failed
DLGN Get data logger log file by name
Syntax of command:
DLGN;<name>;<format>;<clear>;<first_dataset>
Syntax of response:
DLGN;<error_code>
Description:
Returns the content of the specified data logger log file. Starts with first_dataset.
Log file data can be deleted after reading is finished.
Parameter:
Input:
Variable
Variable Type
Description
name
string
Name of data logger (max 16 char)
format
string
If 'H': get info header 1 & 2 + comment + data
If 'N': get log file name + data
clear
string
If 'C': clear data logger content
first_dataset
uint32
First data set number to be read
Output:
Variable
Variable Type
Description
error_code
uint16
0: no error occurred, else command failed
<name>.dlf
file
dlf-file containing the logger data