69
English
CCR Diving
Max Operating
Depth MOD
Change the O
2
% mix by (+)
and (–)
ppO
2
max
3. Change the oxygen fraction in increments of 1% by pushing or . Subgear XP-3G will
display the current fraction of oxygen, the maximum partial pressure limit (ppO
2
max) and the MOD.
4. Confirm the selected percentage with .
Change the ppO
2
max by (+) and
(–)
5. By pushing or you can change the ppO
2
max for the chosen fraction of oxygen down to
1.0bar. Subgear XP-3G will now display the corresponding MOD for the new ppO
2
max.
6. Confirm your ppO
2
max settings with .
Functions during a CCR dive
WARNING
During dives with several gas mixtures, always make sure you are breathing from the tank you intended to breath
from.Markallyourtanksandregulators,sotheycanundernocircumstancesbemixedup!Beforeeverydive
and after changing a tank, make sure that each gas mixture is set to the correct value for the corresponding tank.
Predictive decompression prognosis
The calculation of decompression data is based on the assumption that the SP1 / SP2 change(s) will
be performed at the previously selected switch depth(s) (setpoint 1/2). If a diver ignores a required
change or changes the SP1 / SP2 belatedly, Subgear XP-3G will readjust the decompression calculation
accordingly. In case of an ignored switch the dive computer will then base its calculations on the
assumption that the diver will ascend to the surface with the currently selected SP1 / SP2.