DC operation (car battery)
The car battery cable PC-V66 (option) is required to operate the splicer on DC power
(car battery). Contact a sales representative.
DC input
Battery refreshing
バッテリユニットリフレッシュ
14
BACK
2 / 2
Maintenance
Restore Data
Self inspection
Battery Refresh
To extend battery life it is recommended that batteries be completely drained before
re-charging. Otherwise the battery module loses its ability to fully recharge.
• Battery refreshing can be done in Maintenance menu.
If “Battery Refresh” is selected, this
screen is displayed and battery refreshing
starts. When refreshing is complete, the
TYPE-66 is automatically turned off.
Connect the PS-66 power supply module
to the BU-66 battery module for charging.
Battery Refresh
PAGE
MOVE
SELECT
Refresh time depends on the amount of
charge remaining in the battery module. A
fully charged battery module takes about
7.5 hours to refresh.
A fully charged BU-66L doubles this time.
Precautions for battery module
• Before using the battery module for the first time, charge the battery module.
(The battery is not fully charged before shipping.)
• The battery module is consumables. Repeated charging and discharging decreases
battery life.
• Store the battery module within the following temperature range. Failure to do so may
lead to deterioration in performance.
*Battery module storage temperature range:
-20°C ~ +50°C (if stored for less than 3 months)
-20°C ~ +30°C (if stored for less than 1 year)