EasyManua.ls Logo

Sumitomo TYPE-66M12 - Battery Management and Refreshing

Sumitomo TYPE-66M12
68 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DC operation (car battery)
The car battery cable PC-V66 (option) is required to operate the splicer on DC power
(car battery). Contact a sales representative.
DC input
Battery refreshing
ッテリユニットリフレッシュ
14
BACK
2 / 2
Maintenance
Restore Data
Self inspection
Battery Refresh
To extend battery life it is recommended that batteries be completely drained before
re-charging. Otherwise the battery module loses its ability to fully recharge.
• Battery refreshing can be done in Maintenance menu.
If “Battery Refresh” is selected, this
screen is displayed and battery refreshing
starts. When refreshing is complete, the
TYPE-66 is automatically turned off.
Connect the PS-66 power supply module
to the BU-66 battery module for charging.
Battery Refresh
PAGE
MOVE
SELECT
Refresh time depends on the amount of
charge remaining in the battery module. A
fully charged battery module takes about
7.5 hours to refresh.
A fully charged BU-66L doubles this time.
Precautions for battery module
Before using the battery module for the first time, charge the battery module.
(The battery is not fully charged before shipping.)
The battery module is consumables. Repeated charging and discharging decreases
battery life.
Store the battery module within the following temperature range. Failure to do so may
lead to deterioration in performance.
*Battery module storage temperature range:
-20°C ~ +50°C (if stored for less than 3 months)
-20°C ~ +30°C (if stored for less than 1 year)