Error message list
Please contact maintenance service center when it is not recovered if you take the
measures below.
Error message Description and measure
Alignment Error [Description]
(L)(R)(LR) There is dust in the V-groove.
There is dust on the fiber.
[Measure]
Clean the V-groove.
Re-cleave the fiber.
Brightness Error [Description]
Brightness Various Error The splicer failed in LED brightness adjustment.
LED error [Measure]
Clean the LED, the mirror protection glass and the microscope lens.
CAMERA ERROR [Measure]
Turn off the power and turn it on again. If the error still persists,
contact our maintenance service center.
Cut Error (Angle) [Description]
(L)(R)(LR) The cleave angle exceeds the allowable level.
[Measure]
Re-cleave the fiber.
Cut Error (Crack) [Description]
(L)(R)(LR) The splicer detected crack in an end-face inspection
[Measure]
Re-cleave the fiber.
Cut Error (LIP) [Description]
(L)(R)(LR) The splicer detected lip in an end-face inspection
[Measure]
Re-cleave the fiber.
Cut Error (Projection) [Description]
(L)(R)(LR) The splicer detected projection in an end-face inspection
[Measure]
Re-cleave the fiber.
DEVICE ERROR [Description]
The controlboard has a problem.
[Measure]
Please contact our maintenance service center.