Chapter 5 Removing and Replacing Miscellaneous Internal Components 101
14. Connect the front fan assembly cables to the system board connectors.
See FIGURE 5-15 to locate the system board connectors.
Note – Refer to the chassis label for an illustration of the correct routing of the
cables.
15. Connect the interface board SCSI and IDE cables to the system board.
See FIGURE 5-14 to locate the cables.
16. Press the SCSI/IDE cable clamp back down to secure the SCSI interface and IDE
cables.
The cable clamp is attached to the chassis and has a green cap. See FIGURE 5-13 for
the location of this clamp.
17. Connect the PDB wiring harness to the system board.
See FIGURE 5-12 to locate the wiring harness.
18. Place the PCI riser card assembly in position in the server (FIGURE 5-11).
a. Press down on the top of the assembly to fully seat it into the system board.
b. Tighten the two captive screws that secure the PCI riser card assembly to the
system board (
FIGURE 5-11).
19. Insert all PCI cards back into the PCI riser card assembly.
See “Installing a PCI Card” on page 80.
20. Install the air duct and rear fan assembly.
See “Installing or Closing the Air Duct and Rear Fan Assembly” on page 70.
21. Close the rotating service module.
See “Closing the Rotating Service Module” on page 31.
22. Install the server cover.
See “Installing the Server Cover” on page 29.
23. Power on the server.
See “Powering On the Server” on page 20.