Chapter 4 Removing and Replacing Rotating Service Module Components 65
Installing the System Configuration Card Reader
Cluster
1. Place the system configuration card reader cluster in position in the rotating
service module (
FIGURE 4-6).
Ensure that the four tabs are properly inserted into their locations.
2. Using a No. 2 Phillips screwdriver, tighten the two captive screws to secure the
cluster to the rotating service module (
FIGURE 4-6).
3. Plug the cables back in:
a. Plug the IDE cable into the system board.
b. Plug the bezel cables into the SCSI interface board.
c. Plug the DVD power/I
2
C interface ribbon cable into the SCSI interface board.
d. Plug the SCSI interface cable.
4. Press the SCSI/IDE cable clamp back down to secure the SCSI interface and IDE
cables.
The cable clamp is attached to the chassis and has a green cap. See FIGURE 4-4 for the
location of this clamp.
5. Close the rotating service module.
See “Closing the Rotating Service Module” on page 31.
6. Install the server cover.
See “Installing the Server Cover” on page 29.
7. Grip the bezel at the two finger holds and rotate it down to its open position
(
FIGURE 2-4).
8. Install the DVD drive back into the server.
See “Installing a DVD Drive” on page 47.
9. Install the system configuration card back into the system configuration card
reader.
See “Inserting a System Configuration Card” on page 39.
10. Close the bezel door.
11. Power on the server.
See “Powering On the Server” on page 20.