64 Sun Fire V890 Server Rackmounting Guide May 2004
Adjustable wrench
Masking tape or felt tip pen
Antistatic wrist strap
Antistatic mat
Sun Fire V890 Server Owners Guide
Sun Fire V890 Server Service Manual
Using the Short Rear Brackets
The Sun Fire V890 server rackmounting kit for EIA-compliant racks contains two
short rear brackets. These rear brackets are used to install the Sun Fire V890 server
into a 31.5-inch (80-cm) depth (rail-to-rail) rack. The short rear brackets are in a bag
labeled 560-2682-01 in the rackmounting kit.
The following illustration shows the additional short rear brackets.
Preparing the Server
To prepare the server for rackmounting, complete the following tasks:
Power off the system and disconnect the server’s power cords, network cables,
and I/O cables. See the Sun Fire V890 Server Service Manual for instructions.
Remove all power supplies, CPU/Memory boards, I/O fan trays, and CPU fan
trays. See “Remove Components” on page 65.
Remove the side door handles. See “Remove the Handle From Each Side Door”
on page 67.
Remove the fenders and lower side panels. See “Remove the Fenders and Lower
Side Panels” on page 69.
Install the lifting handles. See “Install the Lifting Handles” on page 72.

Table of Contents

Other manuals for Sun Microsystems Sun Fire V890

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sun Microsystems Sun Fire V890 and is the answer not in the manual?

Sun Microsystems Sun Fire V890 Specifications

General IconGeneral
BrandSun Microsystems
ModelSun Fire V890
CategoryServer
LanguageEnglish

Related product manuals