SUNFAR C300 93
C300 series of non-sensor current vector-control inverter manual
2, The channels of running command: communication interface(F0.4=00#2)
3, Communication setting F9.0 is default
4, Communication auxiliary function configuration F9.3=000: the inverter is slave.
9.5.6 Operation Notes:
PLC controls the running of inverter when terminal X0 is on.
The running speed of inverter is 10Hz when terminal X1 is on.
The running speed of inverter is 20Hz when terminal X2 is on.
The running speed of inverter is 500Hz when terminal X3 is on.
The inverter would stop when terminal X5 is on.
9.5.7 Master PLC trapezoidal chart:
( M 8161)
M 8000
[M OV H 0C87 D8120]
[RS D100 K15 D485 K33]
X000
X005
M10
(
T10)
T10
(
M10)
M10
[SET M 8122]
[ F M O V K 0 D 100 K 1 5 ]
[ F M O V K 0 D 5 5 0 K 2 5]
M 8012
X000
[M O V H 1 1 D 1 05]
[M O V H 4 D 1 0 3 ]
M 8000
[M O V H 5 A D 1 00]
[MOV D516 K2M160]
[MOV H0D D114]
[M O V D 515 K 2 M 1 6 8 ]
[M O V K 4 M 160 D 5 3 0 ]
X001
[M O V H 3 D 1 0 8 ]
X003
X002
[ M O V H 0 E 8 D 1 0 9 ]
X002
[ M O V H 0D 0 D 1 09 ]
X001
X003
[M O V H 7 D 1 0 8 ]
[M O V H 1 3 D 1 08 ]
[ M O V H 8 8 D 1 09 ]
X003
X001
X002
[ADD D511 D520 D520 ]
[ADD D512 D520 D520]
[A D D D 5 0 8 D 5 2 0 D 5 2 0 ]
[ADD D505 D520 D520 ]
[M O V K 0 D 5 2 0]
M 8123
M 8123
[Z R S T M 0 M 2 ]
[R S T M 812 3 ]
[BM OV D500 D550 K18 ]
[C M P D 5 30 D 520 M 0]
M1
[M O V K 2 M 100 D 1 1 3 ]
[M OV K2M 108 D112 ]
[M O V D 213 K 4 M 1 0 0 ]
[A D D D 1 0 8 D 2 1 3 D 2 13 ]
[ADD D109 D213 D213 ]
[DMOV K0 D213 ]
[ADD A103 D213 D213 ]
[A D D D 1 0 5 D 2 1 3 D 2 1 3 ]
M 8122
[END]
Fig 9-7 Master PLC trapezoidal chart