SUNFAR C300 17
C300 series of non-sensor current vector-control inverter manual
d-31 Sixth fault record
d-32
Output frequency of last fault
Hz
d-33
Setting frequency of last fault
Hz
d-34
Output current of last fault
A
d-35
Output voltage of last fault
V
d-36
DC voltage of last fault
V
d-37
Temperature of module of last fault
ºC
4.4 Operations
4.4.1. Initialization
(1)Frequency input channel / mode selection[F0.1]
Initialization of inverter is different according to different model. If [F0.0] is 0, the
frequency of inverter is set by keypad.
(2)Operation channel selection[F0.4]
Initialization
of inverter is different according to different model. If F0.4 is 00#0, start
and stop of inverter is controlled by key.
4.4.2. Simply operation
Fig.4-1 simply running
It is forbidden to connect Three-phase power to output terminal U, V and W directly.
M
Motor
U
W
V
R
S
T
Power supply
×
×
×
Three-phase
Breaker
Earth
E