70 SUNFAR C300
C300 series of non-sensor current vector-control inverter manual
0Forbid
It is forbidden to copy the backup data from operation panel to inverter, but this
function doesn’t affect the copy and read parameter function.
1Allow
Don’t modify this parameter without our permission.
It is used for getting some special power for user.
It is always random number.
6.8 wobble freq. running parameter unit
It is used for setting basic characteristics of wobble freq. running.
The first part of LED (form right to left)
0 Function of wobble freq. is invalid.
1 Function of wobble freq. is valid.
When inverter receives running instruction, inverter will run in setting freq. of F7.1.
Then inverter will in wobble freq. running mode after arriving setting time of F7.2.
2 Function of wobble freq. is conditional valid.
When external input terminals are valid (namely one of F3.0~F3.3 is 4), the inverter
will run in wobble freq. running mode. When external input terminals are invalid, the
inverter will run in preset freq. of wobble freq. (F7.1)
The second part of LED: restart mode
0 Restart according to parameters saved before stop
1 Restart
The third part of LED: wobble freq. characteristicsRefer to explanation about
parameter F7.3
0The wobble freq. is fixed 1The wobble freq. is changeable.
The fourth part of LED: Storage characteristic of wobble freq.
0It will not save the running state of wobble freq. after power off
1It will save the running state of wobble freq. after power off
F6.17 Manufactory password Setting range0 ~ 9999
F6.18 User password Setting range0 ~ 9999
F6.19 Reference password Setting range0 ~ 9999
F7.0 Wobbles freq. running mode Setting range 00001112
F7.1 Preset freq. of wobble freq. Setting range0.0 ~ the upper limit freq.
F7.2 Waiting time of preset freq. Setting range0.0 ~ 6000.0s