SUNFAR C300 69
C300 series of non-sensor current vector-control inverter manual
setting linear speed, and displaying other value being positive ratio with the output
frequency.
It is used for rectifying the display value of rotator speed.
This parameter is used for confirming display content of operation panel under
state monitor mode.
It is used for getting check code to query or modify parameters.
It is used for modifying inverter’s parameters to manufacture setting.
0:Parameter initialization is off.
1:When parameter initialization is on, please come back parameter unit
F0 ~ F9 to
manufacture setting.
2:Clean fault records
Running linear velocity(d-10)= F6.9 × output frequency (d-0)
Setting linear velocity(d-11)= F6.9 × Setting frequency (d-6)
F6.10 Close-loop analog coefficient setting Setting range:0.01 ~ 100.0
PID feedback value(d.9)= F6.10 × actual feedback value
PID setting value(d.8)= F6.10 × setting value
F6.11 Rotator speed coefficient setting Setting range: 0.01 ~ 10.00
rotator speed(d.3)= F6.11 × actual output rotator speed
F6.12 Monitor item selection 1 / Main display Setting range:0 ~ 11
F6.13 Monitor item selection 2 / Auxiliary display Setting range:0 ~ 11
F6.14 Query or modify parameters Setting range : 0 ~ 9999
F6.15 Parameter initialization Setting range:0 ~ 2
F6.16 Copy function of parameter Setting range:0 ~ 1