C300 series of non-sensor current vector-control inverter manual
For example, data address of F0.8, F1.8 and F#.8 are 8. But data type of them is
different.
AttentionWhen slaves don’t accomplish order form master, setting data is
0000.
5Order is used for sending control order.
It is fit for routine operation for inverter.
Master Sending
Sending Sequence
0
Heade
r
8
Settin
g
data
1
Slave addr.
9
Settin
g
data
2
Slave add
r
10
Check sum
3
4
11
Check sum
4
Operation orde
r
12
Check sum
5
Operation orde
r
13
Check sum
6 14
Tai l
7
Settin
g
data
Slave responding Sending Sequence
0
Heade
r
9
Runnin
g
data
1
Slave addr.
10
Runnin
g
data
2
Slave add
r
11
Runnin
g
data
3
Slave respondin
g
12
Runnin
g
data
4
State feedback
13
Check sum
5
State feedback
14
Check sum
6
0
15
Check sum
7
Monitor item
16
Check sum
8
Monitor item
17
Tai l
Setting data in master sending is setting freq., which is send form master to slave.
Setting data in slave responding is running parameter, which is send form master. It
is set by parameter F6.12.
¾ See the explanation about list of parameter in chapter five.