49
Specification
AC011E-01
Grid type
TN/TT
Display
LED indicator
Monitoring iSolarCloud App (with Sungrow inverter)
Communication RS485
Charging protocol
Power consumption for standby
< 5 W
Start Mode RFID card/APP
Standard compliance
EN/IEC 61851-1:2019; IEC 61851-21-2:2018
Warranty 5 years
Specification
AC011E-01 L1
AC Input and Output
Max. charge power
11 kW
Nominal voltage
400 V
Nominal grid frequency
50/60 Hz
Max. current
16 A three-phase
Charge connector Plug Type 2
Cable cross-section 5*2.5 mm
2
Cable Length
7 m
protection
Residual current detection 6mA DC
Over load protection
Yes
Over temperature protection
Yes
Surge protection category
II
General Data
Dimensions (W*H*D)
310 mm * 205 mm * 92 mm
Weight 3.8 kg
Mounting method Wall-Mounting/Pole-Mounting (optional)
Impact resistance
IK08
Degree of protection
IP65
Operating ambient temperature
range
-30 to 50 °C
Allowable relative humidity range
(non-condensing)
5 % to 95 %
User Manual 7 Appendix

Other manuals for Sungrow AC011E-01

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow AC011E-01 and is the answer not in the manual?

Sungrow AC011E-01 Specifications

General IconGeneral
ModelAC011E-01
CategoryBattery Charger
Output Power11 kW
Frequency50/60 Hz
Operating Temperature-25°C to +60°C
ProtectionOvervoltage, Overcurrent, Short Circuit, Over Temperature
CommunicationRS485/CAN