EasyManuals Logo

Sungrow SG50CX User Manual

Sungrow SG50CX
129 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
19
If the inverter needs to be transported again, pack it strictly before loading and transport-
ing it.
Do not store the inverter in places susceptible to direct sunlight, rain, and strong electric
field.
Do not place the inverter in places with items that may affect or damage the inverter.
Store the inverter in a clean and dry place to prevent dust and water vapor from eroding.
Do not store the inverter in places with corrosive substances or susceptible to rodents
and insects.
Carry out periodic inspections. Inspection shall be conducted at least once every six
months. If any insect or rodent bites are found, replace the packaging materials in time.
If the inverter has been stored for more than a year, inspection and testing by professio-
nals are required before it can be put into operation.
Please store the inverter according to the storage requirements. Product damage
caused by failure to meet the storage requirements is not covered by the warranty.
User Manual 3 Unpacking and Storage

Table of Contents

Other manuals for Sungrow SG50CX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG50CX and is the answer not in the manual?

Sungrow SG50CX Specifications

General IconGeneral
Max. DC Voltage1100 V
MPPT Voltage Range200 V - 1000 V
Max. Input Current per MPPT26 A
Number of MPPTs4
Rated AC Output Power50 kW
Max. AC Output Current76 A
Frequency50 Hz / 60 Hz
Efficiency98.6%
Start Voltage200 V
Number of DC Inputs per MPPT2
Max. AC Apparent Power55 kVA
AC Voltage Range310 V - 480 V
Power Factor at Rated Power1
Adjustable Power Factor Range0.8 leading - 0.8 lagging
THDi< 3%
DC SwitchYes
AC Surge ProtectionType II
DC Surge ProtectionType II
Protection ClassI
Cooling MethodSmart forced air cooling
Protection DegreeIP66
Protection LevelIP66
Operating Temperature Range-25°C to +60°C
Humidity0-100%
AC Output Voltage3 / N / PE, 220 V / 380 V, 230 V / 400 V

Related product manuals