EasyManuals Logo

Sungrow SG50CX User Manual

Sungrow SG50CX
129 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
II
About This Manual
The manual mainly contains the product information, as well as guidelines for installation,
operation, and maintenance. The manual does not include complete information about the
photovoltaic (PV) system. Readers can get additional information at www.sungrowpower.
com
or on the webpage of the respective component manufacturer.
Validity
This manual is valid for the following model of low-power grid-connected PV string inverters:
SG30CX
SG33CX
SG40CX
SG50CX
SG30CX-NI
SG50CX-NI
It will be referred to as "inverter" hereinafter unless otherwise specified.
Target Group
This manual is intended for professional technicians who are responsible for installation, op-
eration, and maintenance of inverters, and users who need to check inverter parameters.
The inverter must only be installed by professional technicians. The professional technician
is required to meet the following requirements:
Know electronic, electrical wiring and mechanical expertise, and be familiar with electri-
cal and mechanical schematics.
Have received professional training related to the installation and commissioning of elec-
trical equipment.
Be able to quickly respond to hazards or emergencies that occur during installation and
commissioning.
Be familiar with local standards and relevant safety regulations of electrical systems.
Read this manual thoroughly and understand the safety instructions related to
operations.
How to Use This Manual
Please read this manual carefully before using the product and keep it properly at a place
for easy access.
All contents, pictures, marks, and symbols in this manual are owned by SUNGROW. No part
of this document may be reprinted by the non-internal staff of SUNGROW without written
authorization.

Table of Contents

Other manuals for Sungrow SG50CX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG50CX and is the answer not in the manual?

Sungrow SG50CX Specifications

General IconGeneral
Max. DC Voltage1100 V
MPPT Voltage Range200 V - 1000 V
Max. Input Current per MPPT26 A
Number of MPPTs4
Rated AC Output Power50 kW
Max. AC Output Current76 A
Frequency50 Hz / 60 Hz
Efficiency98.6%
Start Voltage200 V
Number of DC Inputs per MPPT2
Max. AC Apparent Power55 kVA
AC Voltage Range310 V - 480 V
Power Factor at Rated Power1
Adjustable Power Factor Range0.8 leading - 0.8 lagging
THDi< 3%
DC SwitchYes
AC Surge ProtectionType II
DC Surge ProtectionType II
Protection ClassI
Cooling MethodSmart forced air cooling
Protection DegreeIP66
Protection LevelIP66
Operating Temperature Range-25°C to +60°C
Humidity0-100%
AC Output Voltage3 / N / PE, 220 V / 380 V, 230 V / 400 V

Related product manuals