3
1.2 Installation Safety
Make sure there is no electrical connection before installation.
Before drilling, avoid the water and electricity wiring in the wall.
Improper installation may cause personal injury!
If the product supports hoisting transport and is hoisted by hoisting tools, no
one is allowed to stay under the product.
When moving the product, be aware of the product weight and keep the balance
to prevent it from tilting or falling.
Before operating the product, must check and ensure that tools to be used have
been maintained regularly.
1.3 Electrical Connection Safety
Before electrical connections, please make sure that the inverter is not dam-
aged, otherwise it may cause danger!
Before electrical connections, please make sure that the inverter switch and all
switches connected to the inverter are set to "OFF", otherwise electric shock
may occur!
The PV string will generate lethal high voltage when exposed to sunlight.
Operators must wear proper personal protective equipment during electrical
connections.
Must ensure that cables are voltage-free with a measuring instrument before
touching DC cables.
Respect all safety instructions listed in relevant documents about PV strings.
The inverter must not be connected to a PV string that requires positive or neg-
ative grounding.
User Manual 1 Safety Instructions

Table of Contents

Other manuals for Sungrow SG50CX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG50CX and is the answer not in the manual?

Sungrow SG50CX Specifications

General IconGeneral
Max. DC Voltage1100 V
MPPT Voltage Range200 V - 1000 V
Max. Input Current per MPPT26 A
Number of MPPTs4
Rated AC Output Power50 kW
Max. AC Output Current76 A
Frequency50 Hz / 60 Hz
Efficiency98.6%
Start Voltage200 V
Number of DC Inputs per MPPT2
Max. AC Apparent Power55 kVA
AC Voltage Range310 V - 480 V
Power Factor at Rated Power1
Adjustable Power Factor Range0.8 leading - 0.8 lagging
THDi< 3%
DC SwitchYes
AC Surge ProtectionType II
DC Surge ProtectionType II
Protection ClassI
Cooling MethodSmart forced air cooling
Protection DegreeIP66
Protection LevelIP66
Operating Temperature Range-25°C to +60°C
Humidity0-100%
AC Output Voltage3 / N / PE, 220 V / 380 V, 230 V / 400 V