EasyManuals Logo

Sungrow SG50CX User Manual

Sungrow SG50CX
129 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
21
4.2 Location Requirements
To a large extent, a proper installation location ensures safe operation, service life, and per-
formance of the inverter.
The inverter with protection rating IP66 can be installed both indoors and outdoors.
The inverter should be installed at a height that allows easy viewing of the LED indicator
panel, as well as easy electrical connection, operation and maintenance.
4.2.1 Installation Environment Requirements
The inverter produces noise during operation, thus it is not recommended to install it in
places for residential purpose. If this cannot be avoided, it is recommended to install the
inverter in a place over 25 meters away from the residential area, or take noise mitigation
measures.
User Manual 4 Mechanical Mounting

Table of Contents

Other manuals for Sungrow SG50CX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG50CX and is the answer not in the manual?

Sungrow SG50CX Specifications

General IconGeneral
Max. DC Voltage1100 V
MPPT Voltage Range200 V - 1000 V
Max. Input Current per MPPT26 A
Number of MPPTs4
Rated AC Output Power50 kW
Max. AC Output Current76 A
Frequency50 Hz / 60 Hz
Efficiency98.6%
Start Voltage200 V
Number of DC Inputs per MPPT2
Max. AC Apparent Power55 kVA
AC Voltage Range310 V - 480 V
Power Factor at Rated Power1
Adjustable Power Factor Range0.8 leading - 0.8 lagging
THDi< 3%
DC SwitchYes
AC Surge ProtectionType II
DC Surge ProtectionType II
Protection ClassI
Cooling MethodSmart forced air cooling
Protection DegreeIP66
Protection LevelIP66
Operating Temperature Range-25°C to +60°C
Humidity0-100%
AC Output Voltage3 / N / PE, 220 V / 380 V, 230 V / 400 V

Related product manuals