Step 2 Loosen the swivel nut of the junction box and select an appropriate seal according to cable
outer diameter. Lead the cable through the swivel nut, seal, and junction box successively.
Outer Diameter D(mm)
Seal
4.5 ~ 6
c
6 ~ 12 a + b
12 ~ 18 b
Step 3 Strip the insulation layer of the Ethernet cable with a wire stripper, and insert the signal wires
to the RJ45 connector(Pin 3 and Pin 6 are for communication connection). Crimp the RJ45
connector with a crimping tool.
Step 4 Insert the RJ45 connector to the RJ45 jack.
5 Electrical Connection User Manual

Table of Contents

Other manuals for Sungrow SG50CX

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG50CX and is the answer not in the manual?

Sungrow SG50CX Specifications

General IconGeneral
Max. DC Voltage1100 V
MPPT Voltage Range200 V - 1000 V
Max. Input Current per MPPT26 A
Number of MPPTs4
Rated AC Output Power50 kW
Max. AC Output Current76 A
Frequency50 Hz / 60 Hz
Efficiency98.6%
Start Voltage200 V
Number of DC Inputs per MPPT2
Max. AC Apparent Power55 kVA
AC Voltage Range310 V - 480 V
Power Factor at Rated Power1
Adjustable Power Factor Range0.8 leading - 0.8 lagging
THDi< 3%
DC SwitchYes
AC Surge ProtectionType II
DC Surge ProtectionType II
Protection ClassI
Cooling MethodSmart forced air cooling
Protection DegreeIP66
Protection LevelIP66
Operating Temperature Range-25°C to +60°C
Humidity0-100%
AC Output Voltage3 / N / PE, 220 V / 380 V, 230 V / 400 V