23
4.5 Typical Application: APP2 Four-Sacle Mode
4.5.1 System Diagram A for APP2 Four-Sacle Mode without Mixing Bin
Parameter [300] ‘Application Mode’= ‘1: APP2 Four-scale Mode’.
Parameter [408] ‘Mixing Time Before Mixing Bin Auto-dumping =0.
Feeding Hopper M1-M4
SP1 High-speed Feeding Gate / SP3 Low-speed Feeding Gate
Weighing Controller
Loadcell
M1
#1
Dumping Gate
M2
#2
M3
#3
M4
#4
Mixing Conveyor
Mixing Conveyor Ready
Control Box
Weighing Hopper #1-#4