53
Appendix B. Register Table of Host-Slave MODBUS[ASCII/RTU]
Data Name
Attr.
CMD
[HEX]
Description
#1 #2 #3 #4
Materials Selection for
Auto-Batching
R/W 03/10
Bit0 M1
Bit2 M3
Working Recipe No. 40199 R/W 03/10 0~9: Recipe No. 1~10
Static Calibration 41101 W 10
0x01/02/03/04: #1/#2/#3/#4 Start
0x21: End Zero Calibration
0x22: End Load Calibration
AD Value 41003 41023 41043 41063 R 03
Calibrating Weight 41105 41115 41125 41135 W 10 Used for Load Calibration
Net Weight 41209 41211 41213 41215 R 03
Batch Count 41301 41303 41305 41307 R 03
Running State
41225
R 03
Bit1 1: Auto; 0: Manual
Bit15 Special for manufacturer
Running State
Bit0
R 03
1: Running
1: Special for manufacturer
Bit2 1: Non-load Zero Range
Bit4 1: Feeding Ended
1: Doing ‘Zero Fine Adjustment’
Bit6 1: High-speed Feeding
Bit8 1: Low-speed Feeding
Bit10 1: Overload Alarm
1: Negative Deviation Alarm
Bit12 1: Positive Deviation Alarm
Bit14
1: Gross Weight Upper Limit