29
6.3 F1 Settings
6.3.1 Weighing Parameters
No. Sign Range Default Description REG
100 Weight Unit 0~5 2
Weight Unit
0: UserSet; 1: g; 2: kg; 3: t
4: lb[pound]; 5: oz[ounce]
40101
101
Decimal Point
Position
0~3 1
Decimal Point Position
0: 0; 1: 0.0; 2: 0.00; 3: 0.000
40103
102 Scale Capacity 1~999999 10000
#1 Scale Capacity
Max. allowed loading weight of the load
receptor.
Scale CapacityTotal Capacity of Loadcells
Self-weight of Load Receptor.
40105
#2 Scale Capacity 40135
#3 Scale Capacity 40137
#4 Scale Capacity 40139
103 Scale Division 1~50 1
Scale Division
0: 1; 1: 2; 2: 5; 3: 10; 4: 20; 5: 50
40107
104 #1&3 Zero Value
-20000~
+999999
0
[*]
Weigher #1 Zero Value
Only for query.
40109
0
[*]
Weigher #3 Zero Value
Only for query.
40117
105
#1&3 Span
Coefficient
0.0001~
999.9999
1.0000
[*]
Weigher #1 Span Coefficient
Only for query.
40111
1.0000
[*]
Weigher #3 Span Coefficient
Only for query.
40119
106 #2&4 Zero Value
-20000~
+999999
0
[*]
Weigher #2 Zero Value
Only for query.
40113
0
[*]
Weigher #4 Zero Value
Only for query.
40121
107
#2&4 Span
Coefficient
0.0001~
999.9999
1.0000
[*]
Weigher #2 Span Coefficient
Only for query.
40115
1.0000
[*]
Weigher #4 Span Coefficient
Only for query.
40123
[*]: Part-Default operation has no effect on the parameter.