Step3: Weigh the actual weight of the materials in the container on a high-accuracy weigher, then press
the buttonWeightto input the weight value as ‘Calibrating Weight’.
Step4: PressSaveto display and save the new ‘Span Coefficient’ value. If the dumping weight [the
weight of the materials dumped from the weighing hopper] is too small, the operationSavewill be
invalid.
Sign Data Sign Data
Big Digits Real-time Weight [Weight Unit].
Motion
Stable
Weight is dynamic changing.
Weight is stable.
Span Coeff The saved ‘Span Coefficient’ value.
AD Value
Real-time AD Value of weighing
signal.
Cal. Weight Calibrating Weight = Dumping Weight
AD0 Value The AD Value after Feeding ended. AD1 Value The AD Value after Dumping ended.