45
No. Sign Range Default Description REG
DO Function Options
41: Material M1 High-speed Feed
42: Material M1 Low-speed Feed
43: Material M2 High-speed Feed
44: Material M2 Low-speed Feed
45: Material M3 High-speed Feed
46: Material M3 Low-speed Feed
47: Material M4 High-speed Feed
48: Material M4 Low-speed Feed
49: Material M1 Feeding Ended
50: Material M2 Feeding Ended
51: Material M3 Feeding Ended
52: Material M4 Feeding Ended
53: All Materials Feeding Ended
54: Unused
55: Unused
56: Unused
57: Mixing Bin Dump [4-Scale Mode]
58: Mixer Control
59: Mixing Conveyor Control
60: Unused
61: #3 Unused
62: #3 Unused
63: #3 Unused
64: #3 Unused
65: #3 Dump
66: #3 Alarm/Pause
67: #3 Unused
68: #3 Deviation Alarm
69: #3 Positive Deviation Alarm
70: #3 Negative Deviation Alarm
71: #3 Unused
72: #3 Gross Weight Upper Limit Alarm
73: #3 Pause State
74: #3 Running State
75: #3 Stop State
76: #3 Unused
77: #3 Feeding State
78: #3 Unused
79: #3 Unused
80: #3 Unused