57
Parameter Range Default Description
Material Mn
Target Value
0~60000 1000
Set value = 0: Material Mn will not participate in the batching
process.
Mn_SP1 Lead Value
[High-speed Feed]
0~60000 50
Set value = 0: The DO switch ‘High-speed Feed’ will not
participate in the feeding process.
Set value > 0: When ‘Feeding Weight≥(Target Value-SP1
Lead)’ in the feeding process, the DO switch ‘High-speed Feed’
will turn off automatically.
The auto-feeding process of the first batch after ‘Start’ signal
inputted:
If ‘Net Weight≥(Target Value – SP3 Fall)’, then the material
Mn’s auto-feeding process of the first batch will be skipped.
If ‘(Target Value × 50%)≤Net Weight≤(Target Value – SP3
Fall)’, then the DO switche ‘Low-speed Feed’ will not
participate in the material Mn’s auto-feeding process of the
first batch, and only the DO switch ‘Low-speed Feed’ will
do.
Mn_SP3 Fall Value
[Low-speed Feed]
0~60000 50
When ‘Feeding Weight≥(Target Value -SP3 Fall)’ in the
feeding process, the DO switch ‘Low-speed Feed’ will turn off
automatically.
Note: It has one more decimal than ‘Target Value’.