IntelliShot & FlexoShot: Operations Manual Page 26
The dispensers default setting is selective mode. If temperature adjustments are required, the
dispenser must be changed to continuous display mode.
CHANGING THE SIDE CONSOLE DISPLAY MODE
Selective Mode to Continuous Display Mode
Press and hold the warm (bottom) side console button for a few seconds until a beep is heard.
“d1” will be displayed for a few seconds and the dispenser will be in continuous display mode.
Continuous Display Mode to Selective Mode
Press and hold the warm (bottom) side console button for a few seconds until a beep is heard.
“d2” will be displayed for a few seconds and the dispenser will be in selective mode.
ADJUSTING THE TEMPERATURE
The temperature settings range from 0 (off) to 12 (coldest). A refrigeration setting of 07 equals 36°F
(2.2°C). Adjustments should be made in single increments and the dispenser left to stabilize before
making any further adjustments. The dispenser’s default setting is selective mode, which must be
changed to continuous display mode to adjust the temperature.
Increasing the Temperature
1. The side console must be in continuous display mode. (See above for instructions.)
2. Press the warm button once to display the current refrigeration setting (e.g., 07). Press the
button again to decrease the setting by 1 to make it warmer. Under normal operating
conditions, the lower and higher temperature settings should never be used.
3. Wait 4-6 hours for the new temperature to stabilize. If necessary, repeat the procedure and wait
another 4-6 hours.
4. When the adjustment is complete, switch the dispenser to selective mode. (See above for
instructions.)
Decreasing the Temperature
1. The side console must be in continuous display mode. (See above for instructions.)
2. Press the cool button once to display the current refrigeration setting (e.g., 07). Press the
button again to increase the setting by 1 to make it cooler. Under normal operating conditions,
the lower and higher temperature settings should never be used.
3. Wait 4-6 hours for the new temperature to stabilize. If necessary, repeat the procedure and wait
another 4-6 hours.
4. When the adjustment is complete, switch the dispenser to selective mode. (See above for
instructions.)