ELECTRICAL SYSTEM 6-17
CARBON BRUSHES
Measure the length of the carbon brushes as shown. If the mea-
surement is less then the service limit, replace the carbon
brushes with new ones.
$ Brush length
Service Limit: 4.5 mm
" 09900-20102: Vernier calipers (200 mm)
RECTIFIER
Measure the voltage among the terminal
1 and the other termi-
nals (P
1
, P
2
, P
3
and P
4
). Put the tester lead on the terminal
1
and the other lead to P
1
, P
2
, P
3
and P
4
terminals. Observe the
reading and then switch the leads. Perform other side tests
among the terminal
2 and the other terminals (P
1
, P
2
, P
3
and
P
4
), as described below. If the voltage measured is excessively
out of specification, replace the rectifier.
" 09900-25008: Multi circuit tester set
, Tester knob indication: Diode test (-)
IC REGULATOR
Measure the voltage between terminal “F” and terminal “B”.
Refer to the following table.
If the voltage measured is excessively out of specification,
replace the IC regulator.
F : Rotor coil terminal
B : Battery terminal
" 09900-25008: Multi circuit tester set
, Tester knob indication: Diode test (-)
NOTE:
If the tester reads under 1.4 V, replace its battery when the
tester probes are not connected.
Terminal – Terminal Voltage
1
+ —
- P
1
, P
2
, P
3
1.4 – 1.5 V
1
- —
+ P
1
, P
2
, P
3
0.4 – 0.5 V
2
+ —
- P
1
, P
2
, P
3
0.4 – 0.5 V
2
- —
+ P
1
, P
2
, P
3
1.4 – 1.5 V
P1
P2 P3
Terminal – Terminal Voltage
B
+ —
- F Approx. 1.4 V
B
- —
+
F Approx. 0.5 V
F
B