EasyManuals Logo

Sym PA12B User Manual

Sym PA12B
231 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #199 background imageLoading...
Page #199 background image
13. Electrical System
13-6
Battery voltage inspection
Use the digital voltmeter or multi meter to
measure the battery voltage.
Voltage
Fully charged13.0~13.2V (20°C)
Insufficiently chargedBelow 12.3V (20°C)
Charging
Remove the battery cell caps.
Connect the charger positive (+) cable to the
battery positive (+) terminal.
Connect the charger negative (-) cable to the
battery negative (-) terminal.
Warning
z Avoid any fire near the battery during
charging.
z Before or after charging, always turn off
the charging machine to avoid explosion
caused by sparks.
z Follow the regulated charging current and
time shown on the battery.
Caution
z Do not charge the battery quickly except
for emergency situation.
z Confirm the charging current and time
before charging the battery.
z Excessive charging current or time will
damage the battery.
z After charging the battery, wait for 30
minutes and then measure the battery
voltage.
After installing the battery, coat the terminal
with grease to avoid oxidation.
To this chapter contents

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sym PA12B and is the answer not in the manual?

Sym PA12B Specifications

General IconGeneral
BrandSym
ModelPA12B
CategoryMotorcycle
LanguageEnglish

Related product manuals