TMSL 097-45018-02 Issue 3: Mar 96
Page 14
ACTIVATE USER
(ACT-USER)
MESSAGE CATEGORY: ADMINISTRATION
TYPE: INPUT
This command allows the user to log on and begin a session.
Note:
During a session, if no activity is detected for five minutes, the system will initiate a CANCEL
USER and log the user off.
COMMAND
ACT-USER:[<tid>]:SUPER:<ctag>::<pid>;
pid: password identification; pid is limited to a maximum of 10 (upper, lower, or
mixed case) characters
Example:
ACT-USER::SUPER:155::CASSIOPEIA;
This example, tagged as command 155, logs onto the designated
<tid>
with the password CAS-
SIOPEIA and begins a session.
COMPLETED RESPONSE
<sid> <date> <time>
M <ctag> COMPLD
;
Example:
TELECOMSOLUTIONS 95-12-08 15:04:13
M 155 COMPLD
;