TMSL 097-45018-02 Issue 3: Mar 96
Page 78
RETRIEVE PARAMETER T1
(RTRV-PRMTR-T1)
MESSAGE CATEGORY: PROVISIONING
TYPE: INPUT/RESPONSE
This command retrieves and displays the facility parameter values for priority, reference type, framing,
and CRC that are stored in the system database.
COMMAND
RTRV-PRMTR-T1:[<tid>]:<aid>:<ctag>;
aid: MRC-1-x = Multi-Reference Controller A (x = span 1 to 4 or ALL)
MRC-2-x = Multi-Reference Controller B (x = span 1 to 4 or ALL)
PSM-x-y = Precision Sync Monitor card (x = 1 to 9, y = span 1 to 4 or
ALL)
Example:
RTRV-PRMTR-T1::MRC-1-2:154;
This example, tagged as command 154, displays the facility parameters for span 2 of MRC-A.
COMPLETED RESPONSE
If no facilities are assigned or equipped, the response is:
<sid> <date> <time>
M <ctag> COMPLD
;
If the aid is MRC-1-x or MRC-2-x, and E1 is the input, and one or more facilities are assigned or
equipped, the response is:
<sid> <date> <time>
M <ctag> COMPLD
[ "<aid>:,,,,,,,,<priority>,<type>,<fmode>,,<crcmode>"] ...
"<aid>:,,,,,,,,<priority>,<type>,<fmode>,,<crcmode>" ...
;
If the aid is MRC-1-x or MRC-2-x, and analog is the input, and one or more facilities are assigned or
equipped, the response is:
<sid> <date> <time>
M <ctag> COMPLD
[ "<aid>:,,,,,,,,<priority>,<type>"] ...
"<aid>:,,,,,,,,<priority>,<type>" ...
;