Page 27
INITIALIZE SYSTEM
(INIT-SYS)
MESSAGE CATEGORY: SURVEILLANCE
TYPE: INPUT/RESPONSE
This command performs a Òcold restartÓ by unconditionally executing the same routine performed on
power-up. The cold restart initializes the system processor registers, which are on the MIS card, to the
highest initialization level (9). All information except the sid, tid, date, and time are cleared. (The SET-
ATTR-LOG command clears only the 64-event system log, and the INIT-REG-T1 command clears specif-
ic registers.) Use INIT-SYS with care.
COMMAND
INIT-SYS:[<tid>]:MIS:<ctag>::9;
Example:
INIT-SYS::MIS:110::9;
This example, tagged as command 110, erases all system information (which is stored on the MIS
card) except the sid, tid, date, and time.
COMPLETED RESPONSE
<sid> <date> <time>
M <ctag> COMPLD
;
Example:
TELECOMSOLUTIONS 95-12-08 15:41:32
M 110 COMPLD
;
ERROR RESPONSE
<sid> <date> <time>
M <ctag> DENY
<errcde>
;

Table of Contents

Other manuals for Symmetricom TimeProvider 500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 500 series and is the answer not in the manual?

Symmetricom TimeProvider 500 series Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 500 series
CategoryData Loggers
LanguageEnglish

Related product manuals