TMSL 097-45018-02 Issue 3: Mar 96
Page 2
language used in this practice is Transaction Lan-
guage 1 (TL1). A Maintenance Interface, System
(MIS) card (p/n 090-45018-14) must be installed in
the DCD-500 series system, and the DCD system
used in conjunction with the NAS software to use the
tools and information presented here. Any command
pertaining to a speciÞc DCD card (e.g., MRC-E or
PSM-E) requires that the speciÞed card be installed.
1.02
This document is reissued for the following
reasons; changes and additions are marked with
change bars:
Update the following commands to include pa-
rameters for the MRC-EA card:
EDIT PARAMETER T1
SET-TH-T1
SET-ATTR-T1
INIT-REG-T1
RTRV-PRMTR-T1
RTRV-COND-T1
RTRV-ALM-T1
RTRV-ATTR-T1
RTRV-TH-T1
Update documentation where necessary to in-
clude information regarding the MRC-EA card.
Update Table A to include the new parameters
2. USING THIS PRACTICE
2.01
Part 3, Description, describes how to use the
commands and read the responses, including: expla-
nations of the typestyle conventions and syntax, Þnd-
ing a command to perform a desired task, deÞnitions
of the parameters, and other useful information.
2.02
Part 4, Commands, contains the commands,
each one starting at the top of a page. Each command
has a description, a format, examples, values for the
parameters, and responses to the command.
3. DESCRIPTION
A. Conventions
3.01
The syntax and language structure used with
the 500 series systems comply with speciÞcations in
BellcoreÕs TR-TSY-000831, Section 12.1 of OTGR Is-
sue 2, Feb. 1988. As a subset of the ITUÕs MML (Man-
Machine Language), the language speciÞes Applica-
tions Messages which allow communication between
an OS (Operations System) and an NE (Network El-
ement) such as one of the 500 series systems.
3.02
The following conventions are used in this
manual to deÞne the syntax of input and response
messages:
< > enclose parameters which must be used
[ ] enclose optional parameter(s)
{ } enclose a series of parameters, at least one of
which must be used
| separates a list of parameters within the { }
symbols, of which one and only one parame-
ter may be selected
" " enclose a report of an alarm or event
: separates parameter blocks
... indicates one or more parameters are re-
peated an appropriate number of times, and
hence are omitted
, separates parameters within a block
; terminates a command and causes execution
of the command
B. Application Message Types
3.03
Two TL1 standard types of messages are used:
a.
Input/Response
, a command with valid pa-
rameters is input to the 500 series system and
a response message is returned.
b.
Automatic
, a message is generated by the 500
series system, stored in the Event Log, and
sent to the Communications Port.

Table of Contents

Other manuals for Symmetricom TimeProvider 500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 500 series and is the answer not in the manual?

Symmetricom TimeProvider 500 series Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 500 series
CategoryData Loggers
LanguageEnglish

Related product manuals