Issue 3: Mar 96 TMSL 097-45018-02
Page 33
RESTORE T1
(RST-T1)
MESSAGE CATEGORY: SURVEILLANCE
TYPE: INPUT/RESPONSE
This command restores an equipment unit or facility into service from a maintenance state.
COMMAND
RST-T1:[<tid>]:<aid>:<ctag>;
aid: MRC-1-x = Multi-Reference Controller A (x = span 1 to 4 or ALL)
MRC-2-x = Multi-Reference Controller B (x = span 1 to 4 or ALL)
PSM-x-y = Precision Sync Monitor card (x = 1 to 9, y = span 1 to 4
or ALL)
Example:
RST-T1::PSM-1-3:134;
This example, tagged as command 134, restores PSM-1, span 3 to service.
COMPLETED RESPONSE
<sid> <date> <time>
M <ctag> COMPLD
;
Example:
TELECOMSOLUTIONS 95-01-11 15:53:12
M 134 COMPLD
;
ERROR RESPONSE
<sid> <date> <time>
M <ctag> DENY
<errcde>
;