Issue 3: Mar 96 TMSL 097-45018-02
Page 59
REPORT EVENT
(REPT-EVT)
MESSAGE CATEGORY: SURVEILLANCE
TYPE: AUTOMATIC
This message reports the occurrence of nonalarmed events, including the access identifier, the severity
of the alarm, the type of condition, whether it affects service, and a short description of the alarm.
MESSAGE FORMAT
<sid> <date> <time>
<atag> REPT EVT {EQPT|T1}
"<aid>:<condtype>,<condeff>:<conddescr>"
;
aid: MRC-1-x = Multi-Reference Controller A (x = span 1 to 4)
MRC-2-x = Multi-Reference Controller B (x = span 1 to 4)
PSM-x-y = Precision Sync Monitor card (x = 1 to 9, y = span 1 to 4
or ALL)
CLK-1 = clock card A
CLK-2 = clock card B
condtype: AIS = alarm indication signal
FFREQ = fractional frequency exceeded for ST A or ST B
LOS = loss of signal
SFI = loss of stratum input
TBPV = threshold violation for BPVs
TCRC = threshold violation for CRC errors
TFFREQ = threshold for fractional frequency has been exceeded
TMTIE = an MTIE threshold has been exceeded
TMTIE1 = threshold for MTIE 1 second has been exceeded
TMTIE4 = threshold for MTIE 4 seconds has been exceeded
TMTIE16 = threshold for MTIE 16 seconds has been exceeded
TMTIE64 = threshold for MTIE 64 seconds has been exceeded
TMTIE128 = threshold for MTIE 128 seconds has been exceeded
TMTIE512 = threshold for MTIE 512 seconds has been exceeded
TMTIE900 = threshold for MTIE 900 seconds has been exceeded
TOOF = threshold for OOFs has been exceeded
TTVAR1 = time variance for TVAR 1 second has been exceeded
TTVAR4 = time variance for TVAR 4 seconds has been exceeded
TTVAR16 = time variance for TVAR 16 seconds has been exceeded
TTVAR64 = time variance for TVAR 64 seconds has been exceeded
TTVAR128 = time variance for TVAR 128 seconds has been exceeded
WKSWPRx = working facility switched back to working status
(x = equipment number)
condeff: CL = standing condition cleared
SC = standing condition raised