Issue 3: Mar 96 TMSL 097-45018-02
Page 47
RETRIEVE ALARMS
(RTRV-ALM-{ALL|EQPT|T1})
MESSAGE CATEGORY: SYSTEM MAINTENANCE
TYPE: INPUT/RESPONSE
This command lists all the alarms in any equipment or facility in a system (RTRV-ALM-ALL), specific
equipment alarms (RTRV-ALM-EQPT), or specific facilities (RTRV-ALM-T1). The optional parameters
specify alarms by severity, type, or whether they affect service. If a piece of equipment is not in alarm,
use the RTRV-COND command to retrieve its condition. Equipment that does not respond to either com-
mand is not installed.
COMMAND
RTRV-ALM-{ALL|EQPT|T1}:[<tid>]:<aid>:<ctag>[::[<ntfcncde>],
[<condtype>],[<srveff>]][,,,];
Note: The <aid> field is optional for RTRV-ALM-ALL.
aid: For RTRV-ALM-ALL:
ALL = all DCD-500 equipment types or states
<null> = all
aid: For RTRV-ALM-EQPT:
EXPANS = expansion shelf
FUSE-1 = fuse A
FUSE-2 = fuse B
MASTER = master shelf
MRC-1 = Multi-Reference Controller A
MRC-2 = Multi-Reference Controller B
PSM-x = Precision Sync Monitor card (x = 1 to 9)
MIS = Maintenance Interface, System
CLK-1 = Stratum clock unit A
CLK-2 = Stratum clock unit B
GTI-1 = GTI installed in the A slot
GTI-2 = GTI installed in the B slot
SYSTEM = all clocks
ALL = all equipment
aid: For RTRV-ALM-T1:
MRC-1-x = Multi-Reference Controller A (x = span 1 to 4 or ALL)
MRC-2-x = Multi-Reference Controller B (x = span 1 to 4 or ALL)
PSM-x-y = Precision Sync Monitor card (x = 1 to 9, y = span 1 to 4
or ALL)
ntfcncde: CR = critical alarm
MJ = major alarm
MN = minor alarm
<null> = all ntfcncdes
ntfcncde: For RTRV-ALM-ALL only:
<null> = all ntfcncdes