Issue 3: Mar 96 TMSL 097-45018-02
Page 31
REMOVE T1
(RMV-T1)
MESSAGE CATEGORY: SURVEILLANCE
TYPE: INPUT/RESPONSE
This command removes an equipment unit or facility from service, and places it into a maintenance
state. When the equipment or facility is in a maintenance state, service-affecting diagnostic routines may
be performed or the unit may be replaced. No alarms are generated at the near end office as a result of
this command.
COMMAND
RMV-T1:[<tid>]:<aid>:<ctag>;
aid: MRC-1-x = Multi-Reference Controller A (x = span 1 to 4 or ALL)
MRC-2-x = Multi-Reference Controller B (x = span 1 to 4 or ALL)
PSM-x-y = Precision Sync Monitor card (x = 1 to 9, y = span 1 to 4
or ALL)
Example:
RMV-T1::PSM-1-3:133;
This example, tagged as command 133, removes PSM-1, span 3 from service.
COMPLETED RESPONSE
<sid> <date> <time>
M <ctag> COMPLD
;
Example:
TELECOMSOLUTIONS 95-01-11 15:48:14
M 133 COMPLD
;
ERROR RESPONSE
<sid> <date> <time>
M <ctag> DENY
<errcde>
;

Table of Contents

Other manuals for Symmetricom TimeProvider 500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 500 series and is the answer not in the manual?

Symmetricom TimeProvider 500 series Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 500 series
CategoryData Loggers
LanguageEnglish

Related product manuals