TMSL 097-45018-02 Issue 3: Mar 96
Page 20
EDIT EQUIPMENT
(ED-EQPT)
MESSAGE CATEGORY: ADMINISTRATION
TYPE: INPUT
This command allows the user to select the communications device type.
COMMAND
ED-EQPT:[<tid>]:<aid>:<ctag>::[<baud>],[<monmode>], [<keepalive>],
[<comtype>],[<endoftext>],[<localecho>],[<compri>];
where: aid: COM-1 = COM port 1
COM-2 = COM port 2
COM-3 = COM port 3
baud: 1200 = 1200 bps (factory set for Ports 1 and 3)
9600 = 9600 bps
<null> = no change
monmode: ALW = allows a port to view data traffic associated with other user ports
in real-time
INH = inhibits a port from viewing data traffic associated with other
user ports in real-time (factory set for all ports)
<null> = no change
keepalive: ALW = allows a port to autonomously output a COMPL message every
15 to 20 minutes
INH = inhibits a port from autonomously outputting a COMPL message
every 15 to 20 minutes (factory set for all ports)
<null> = no change
comtype: X25 = PAD
MODEM = modem
TERM = dumb terminal (factory set for all ports at powerup)
<null> = no change
endoftext: 0 to 0xFF = sets the 1 character at the end-of-text message. This character
does not replace the TL1 end-of-text terminator (;). 0 indicates no
end-of-text message (factory set for all ports); 0xFF is a hexadec-
imal number range (the prefix 0xFF is not required)
localecho ALW = allows local echo
INH = inhibits local echo (factory set for all ports)
<null> = no change
compri: 0 = inhibits alarm/event messages from being transmitted from a
port
1, 2, or 3 = allows alarm/event messages to be transmitted from a port; 1 is
the highest priority, 3 the lowest (factory setting is 1 for ports
1 and 2, 0 for port 3)
<null> = no change