Issue 3: Mar 96 TMSL 097-45018-02
Page 21
EDIT EQUIPMENT (Contd)
Example:
ED-EQPT::COM-1:115::9600,,X.25,,,;
This example, tagged as command 115, identifies port COM1 as set for 9600 baud, using a PAD as the com-
munications device, and using the factory settings for the remaining parameters.
COMPLETED RESPONSE
<sid> <date> <time>
M <ctag> COMPLD
;
Example:
TELECOMSOLUTIONS 95-12-08 15:04:13
M 170 COMPLD
;
ERROR RESPONSE
<sid> <date> <time>
M <ctag> DENY
<errcde>
;
errcde: ENEQ = not equipped
IIAC = invalid aid
ICNV = command not valid
IICT = invalid ctag
IDNV = data not valid
IISP = invalid syntax or punctuation
IITA = invalid tid
INUP = unimplemented non-null parameter
SARB = system resources are busy
SCSN = invalid sequence
SDNA = duplex unit not available
SROF = requested operation failed
SNVS = not in valid state
Example:
TELECOMSOLUTIONS 95-12-08 15:12:47
M 170 DENY
IISP
;

Table of Contents

Other manuals for Symmetricom TimeProvider 500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 500 series and is the answer not in the manual?

Symmetricom TimeProvider 500 series Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 500 series
CategoryData Loggers
LanguageEnglish

Related product manuals