SET ATTRIBUTE T1
(SET-ATTR-T1)
MESSAGE CATEGORY: SURVEILLANCE
TYPE: INPUT/RESPONSE
This command sets the notification code associated with the specified event. This attribute governs
whether the event is reported automatically. Alarmed events are reported automatically by the REPORT
ALARM message.
COMMAND
SET-ATTR-T1:[<tid>]:<aid>:<ctag>::[<ntfcncde>],[<condtype>];
aid: MRC-1-x = Multi-Reference Controller A (x = span 1 to 4 or ALL)
MRC-2-x = Multi-Reference Controller B (x = span 1 to 4 or ALL)
PSM-x-y = Precision Sync Monitor card (x = 1 to 9, y = span 1 to 4 or ALL)
ntfcncde: CR = critical alarm
MJ = major alarm
MN = minor alarm
NA = not alarmed
<null> = not alarmed
condtype: AIS = alarm indication signal
BPV = bipolar violations
CRC = cyclic redundancy check errors
OOF = out of frame errors
LOS = loss of signal
<null> = all condtypes
Note: If the aid is MRC-1-x or MRC-2-x, the condtypes AIS, BPV, CRC, OOF, and LOS
are to be used only if E1 is selected as the input; if analog is the input, and AIS, BPV,
CRC, OOF, or LOS are the condition types, the command will be denied.
condtype: For PSM only:
MTIE1 = maximum time interval error at 1 second
MTIE4 = maximum time interval error at 4 seconds
MTIE16 = maximum time interval error at 16 seconds
MTIE64 = maximum time interval error at 64 seconds
MTIE128 = maximum time interval error at 128 seconds
MTIE512 = maximum time interval error at 512 seconds
MTIE900 = maximum time interval error at 900 seconds
TVAR1 = time variance error at 1 second
TVAR4 = time variance error at 4 seconds
TVAR16 = time variance error at 16 seconds
TVAR64 = time variance error at 64 seconds
TVAR128 = time variance error at 128 seconds
<null> = all condtypes