TMSL 097-45018-02 Issue 3: Mar 96
Page 42
SET SOURCE IDENTIFIER
(SET-SID)
MESSAGE CATEGORY: ADMINISTRATION
TYPE: INPUT/RESPONSE
This command sets the system identification, or source identifier. The sid is included in every message
sent by the system. The target identifier (tid) in a command is the sid of the system where the command
is targeted. (The MIS card retains the sid for six to eight hours after the card is removed from the shelf.)
Note: The sids on the expansion shelves are automatically assigned. The expansion shelf sids are as
follows:
<tid>E1 = Expansion shelf #1
<tid>E2 = Expansion shelf #2
<tid>E3 = Expansion shelf #3
COMMAND
SET-SID:[<tid>]::<ctag>:<sid>;
Example:
SET-SID:::119:TELECOMSOLUTIONS2;
This example, tagged as command 119, sets the sid as TELECOMSOLUTIONS2.
COMPLETED RESPONSE
<sid> <date> <time>
M <ctag> COMPLD
;
Example:
TELECOMSOLUTIONS2 95-12-08 16:37:08
M 119 COMPLD
;
ERROR RESPONSE
<sid> <date> <time>
M <ctag> DENY
<errcde>
;

Table of Contents

Other manuals for Symmetricom TimeProvider 500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 500 series and is the answer not in the manual?

Symmetricom TimeProvider 500 series Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 500 series
CategoryData Loggers
LanguageEnglish

Related product manuals