Issue 3: Mar 96 TMSL 097-45018-02
Page 23
EDIT PARAMETER T1 (Contd)
ED-PRMTR-T1::MRC-2-2:154:1,NETWORK,ANALOG;
This example, tagged as command 154, commands MRC B of span 2 to be the first priority refer-
ence, specifies it is using a network reference and analog signal type; framing mode, and crcmode
parameters are not available and will cause an error to be initiated if input.
COMPLETED RESPONSE
<sid> <date> <time>
M <ctag> COMPLD
;
Example:
TELECOMSOLUTIONS 96-02-08 15:04:14
M 154 COMPLD
;
ERROR RESPONSE
<sid> <date> <time>
M <ctag> DENY
<errcde>
;
errcde: ENEQ = not equipped
IIAC = invalid aid
ICNV = command not valid
IICT = invalid ctag
IDNV = data not valid
IISP = invalid syntax or punctuation
IITA = invalid tid
INUP = unimplemented non-null parameter
SARB = system resources are busy
SCSN = invalid sequence
SDNA = duplex unit not available
SROF = requested operation failed
SNVS = not in valid state
Example:
TELECOMSOLUTIONS 96-02-08 15:04:14
M 154 DENY
IISP
;
REFERENCE
AT&T 365-340-202, August, 1992

Table of Contents

Other manuals for Symmetricom TimeProvider 500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 500 series and is the answer not in the manual?

Symmetricom TimeProvider 500 series Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 500 series
CategoryData Loggers
LanguageEnglish

Related product manuals