RETRIEVE ALARMS (Contd)
conddescr (Contd):
For GTI only:
FUSE OR POWER FAIL = DCD-LPR fuse has blown, or the office
battery has failed
GPS LOSS OF SIGNAL = GPS loss of signal
GPS INVALID = GPS timing is invalid
GTI OUT FAULT = primary rate output of the GTI has been
faulted by a short, improper termination,
or equipment failure
GTI-FAIL = hardware failure; for field service/engi-
neering use only
OSCA LOSS OF SIGNAL = no signal energy detected on OSC input
GTR POWER FAULT = power supply has been faulted by a short,
an open, or equipment failure
GTR COMM FAILURE = The GTI has timed out waiting for a sta-
tus message from the GTR
GTR FAIL = hardware failure; for field service/engi-
neering use only
<null> = no descriptive information exists
Example:
TELECOMSOLUTIONS 96-02-08 15:04:14
M 145 COMPLD
"MRC-1-4:MJ,LOS,NSA"
"MRC-1-4:MJ,MTIE1,NSA"
;
This example, in response to command 145, shows that MRC A, span 4, has two major alarms: loss
of signal, and MTIE 1-second alarms. This also shows that an E1 input is used; if an analog input
was used, the command would have been denied.

Table of Contents

Other manuals for Symmetricom TimeProvider 500 series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom TimeProvider 500 series and is the answer not in the manual?

Symmetricom TimeProvider 500 series Specifications

General IconGeneral
BrandSymmetricom
ModelTimeProvider 500 series
CategoryData Loggers
LanguageEnglish

Related product manuals