TMSL 097-45018-02 Issue 3: Mar 96
Page 68
RETRIEVE CONDITIONS (Contd)
typereq (Contd):
For PSM only:
MTIE1 = maximum time interval error at 1 second
MTIE4 = maximum time interval error at 4 seconds
MTIE16 = maximum time interval error at 16 seconds
MTIE64 = maximum time interval error at 64 seconds
MTIE128 = maximum time interval error at 128 seconds
MTIE512 = maximum time interval error at 512 seconds
MTIE900 = maximum time interval error at 900 seconds
TVAR1 = time variance error at 1 second
TVAR4 = time variance error at 4 seconds
TVAR16 = time variance error at 16 seconds
TVAR64 = time variance error at 64 seconds
TVAR128 = time variance error at 128 seconds
<null> = all maintenance states
typereq: For RTRV-COND-EQPT:
ALLSTAT = all maintenance states
<null> = all maintenance states
Example:
RTRV-COND-T1::MRC-1-ALL:113::BPV;
This example, if E1 is the input, tagged as command 113, retrieves the non-alarmed bipolar viola-
tion status of all spans on MRC-1.
This example, if analog is the input, will be denied and an IDNV error code produced.
COMPLETED RESPONSE
If there are no conditions (that is, if all of the equipment is in alarm or not installed), the format is:
<sid> <date> <time>
M <ctag> COMPLD
;
If there is at least one line of information to report, the format is:
<sid> <date> <time>
M <ctag> COMPLD
["<aid>[,<aidtype>]:[<ntfcncde>],{<condtype>|<state>},
[<serveff>][,,,,,<conddescr>"]]...
"<aid>[,<aidtype>]:[<ntfcncde>],{<condtype>|<state>},
[<serveff>][,,,,,<conddescr>"
;